Div. B › Part 9 › 9.23 › 9.23.9 — Floor Joists

9.23.9.6 — Trimmer Joists

Copied!
(1) Trimmer joists around floor openings shall be doubled when the length of the header joist exceeds 800 mm.
(2) When the header joist exceeds 2 m in length, the size of the trimmer joists shall be determined by calculations.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.