9.26.5.1 — Required Eave Protection

Copied!
(1) Except as provided in Sentence (2), eave protection shall be provided on shingle, shake or tile roofs, extending from the edge of the roof a minimum of 900 mm up the roof slope to a line not less than 300 mm inside the inner face of the exterior wall.
(2) Eave protection is not required,
(a) over unheated garages, carports and porches,
(b) where the roof overhang exceeds 900 mm measured along the roof slope from the edge of the roof to the inner face of the exterior wall,
(c) on roofs of asphalt shingles installed in accordance with Subsection 9.26.8.,
(d) on roofs with slopes of 1 in 1.5 or greater, or
(e) in regions with 3 500 or fewer degree-days.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.