(1) The installation of fireplace inserts and hearth mounted stoves vented through the throat of a fireplace shall conform to CSA B365, “Installation Code for Solid-Fuel-Burning Appliances and Equipment”.
(2) Fireplace inserts and hearth mounted stoves vented through the throat of a fireplace described in Sentence (1) may be installed in existing fireplaces only if a minimum thickness of 190 mm of solid masonry is provided between the smoke chamber and any existing combustible materials, unless the insert is listed for lesser clearances.
(3) A fireplace insert installed in a masonry fireplace shall have,
(a) a listed metal chimney liner installed from the insert collar to the top of the chimney, or
(b) a direct sealed connection to the chimney flue where such provision is part of an insert conforming to Sentence 9.22.10.1. (1).
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.