Div. B › Part 9 › 9.39 › 9.39.1 — Scope

9.39.1.1 — Application

Copied!
(1) This Section applies to,
(a) reinforced concrete slabs that are suspended over cold rooms in basements, and are supported by foundation walls along the perimeter of the slab with no additional interior supports, and
(b) slabs in which the clear span between supporting walls is not more than 2.5 m along the shortest dimension of the slab.
(2) Slabs for conditions other than described in Sentence (1) shall be designed in accordance with Part 4.
(3) This Section does not apply to reinforced concrete slabs intended to support motor vehicles.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.