Div. B › Part 9 › 9.15 › 9.15.5 — Support of Joists and Beams on Masonry Foundation Walls

9.15.5.1 — Support of Floor Joists

Copied!
(1) Except as permitted in Sentence (2), foundation walls of hollow masonry units supporting floor joists shall be capped with,
(a) not less than 50 mm of concrete,
(b) solid masonry units that are 100% solid and not less than 50 mm high, or
(c) semi-solid or hollow solid masonry units that have the top course completely filled with mortar, grout or concrete.
(2) Capping required in Sentence (1) is permitted to be omitted,
(a) in localities where termites are not known to occur,
(b) when the joists are supported on a wood plate not less than 38 mm by 89 mm, and
(c) when the siding overlaps the foundation wall not less than 12 mm.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.