Div. B › Part 9 › 9.26 › 9.26.4 — Flashing at Intersections

9.26.4.5 — Intersection of Shingle Roofs and Walls Other Than Masonry

Copied!
(1) The intersection of shingle roofs and walls clad with other than masonry shall be protected with flashing.
(2) Flashing required in Sentence (1) shall be installed so that it extends up the wall not less than 75 mm behind the sheathing paper, and extends not less than 75 mm horizontally.
(3) Along the slope of the roof, the flashing required in Sentence (1) shall be stepped with not less than a 75 mm head lap.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.