Div. B › Part 9 › 9.27 › 9.27.9 — Hardboard

9.27.9.2 — Thickness

Copied!
(1) Type 1 or 2 hardboard cladding shall be not less than,
(a) 6.0 mm thick when applied over sheathing that provides continuous support, and
(b) 7.5 mm thick when applied to furring or framing members not more than 406 mm o.c.
(2) Type 5 hardboard cladding shall be not less than 9.0 mm thick when applied over sheathing that provides continuous support or over furring or framing members spaced not more than 406 mm o.c.
(3) Where hardboard cladding is grooved, the grooves shall not extend more than 1.5 mm into the minimum required thickness.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.