Div. B › Part 9 › 9.23 › 9.23.10 — Wall Studs

9.23.10.1 — Stud Size and Spacing

Copied!
(1) Except as provided in Sentence (2), the size and spacing of studs shall conform to Table 9.23.10.1.
(2) Studs for walls not listed in Table 9.23.10.1. and supporting roof loads shall conform to Tables A-30 to A-33, provided,
(a) the studs are clad with not less than 9.5 mm thick plywood, OSB or waferboard sheathing on the exterior face, and not less than 12.5 mm gypsum board on the interior face,
(b) solid bridging is provided at not more than 1.2 m o.c,
(c) the studs are fastened to the top and bottom plates with no fewer than three 82 mm toe-nails,
(d) the double top plates are fastened together with not less than 76 mm nails spaced not more than 200 mm o.c,
(e) roof framing members spaced not more than 610 mm are fastened to the top plates with no fewer than four 82 mm toe-nails, and
(f) the bottom plate is fastened to the floor joists, blocking or rim joist with not less than 82 mm nails spaced not more than 200 mm o.c.
Tables & Figures referenced
Table A-30 : Sizes for Spruce-Pine-Fir No. 2 Grade Exterior Wall Studs with Brick Veneer(1)(2) : Forming Part of Sentence 9.23.10.1.(2)
Loading Table A-30…
Table A-33 : Sizes for Northern Species No. 2 Grade Exterior Wall Studs with Siding(1)(2) : Forming Part of Sentence 9.23.10.1.(2)
Loading Table A-33…
Table 9.23.10.1 : Size and Spacing of Studs : Forming Part of Sentence 9.23.10.1.(1)
Loading Table 9.23.10.1…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.