Div. B › Part 9 › 9.4 › 9.4.1 — Structural Design Requirements and Application Limitations

9.4.1.1 — General

Copied!
(1) Subject to the application limitations defined elsewhere in this Part, structural members and their connections shall,
(a) conform to requirements provided elsewhere in this Part,
(b) be designed according to good engineering practice such as provided in the CWC, “Engineering Guide for Wood Frame Construction”, or
(c) be designed according to Part 4 using the loads and deflection and vibration limits specified in,
(i) this Part, or
(ii) Part 4.
(2) Where floor framing is designed in accordance with Clause (1) (b) or (c) and where supporting wall framing and fastenings, or footings, are designed according to Clause (1) (a), the specified live load on the floor according to Table 4.1.5.3. shall not exceed 2.4 kPa.
(3) Location-specific information for structural design, including snow and wind loads and seismic spectral response accelerations, shall be determined according to MMAH Supplementary Standard SB-1, “Climatic and Seismic Data”.
Tables & Figures referenced
Table 4.1.5.3 : Specified Uniformly Distributed Live Loads on an Area of Floor or Roof : Forming Part of Sentence 4.1.5.3.(1)
Loading Table 4.1.5.3…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.