Div. B › Part 9 › 9.27 › 9.27.8 — Plywood

9.27.8.2 — Thickness

Copied!
(1) Plywood cladding shall be not less than 6 mm thick when applied directly to sheathing.
(2) When applied directly to framing or over furring strips, plywood cladding thickness shall conform to Table 9.27.8.2.
(3) The thickness of grooved or textured plywood shall be measured at the point of least thickness.
Tables & Figures referenced
Table 9.27.8.2 : Minimum Plywood Cladding Thickness : Forming Part of Sentence 9.27.8.2.(2)
Loading Table 9.27.8.2…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.