Div. B › Part 9 › 9.23 › 9.23.3 — Fasteners

9.23.3.4 — Nailing of Framing

Copied!
(1) Except as provided in Sentence (2), nailing of framing shall conform to Table 9.23.3.4.
(2) Where the bottom wall plate or sole plate of an exterior wall is not nailed to joists or blocking in conformance with Table 9.23.3.4., the exterior wall may be fastened to the floor framing by,
(a) having plywood, OSB or waferboard sheathing extend down over floor framing and fastened to the floor framing by nails or staples conforming to Article 9.23.3.5., or
(b) tying the wall framing to the floor framing by 50 mm wide galvanized-metal strips,
(i) not less than 0.41 mm in thickness,
(ii) spaced not more than 1.2 m apart, and
(iii) fastened at each end with at least two 63 mm nails.
Tables & Figures referenced
Table 9.23.3.4 : Nailing for Framing : Forming Part of Sentence 9.23.3.4.(1)
Loading Table 9.23.3.4…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.