Div. B › Part 9 › 9.9 › 9.9.7 — Access to Exits

9.9.7.1 — Egress from Roof Area, Podiums, Terraces, Platforms and Contained Open Spaces

Copied!
(1) An access to exit shall be provided from every roof intended for occupancy and from every podium, terrace, platform or contained open space.
(2) Where a roof is intended for an occupant load of more than 60 persons, at least two separate means of egress shall be provided from the roof to stairs designed in conformance with the requirements for exit stairs and located remote from each other.
(3) Where a podium, terrace, platform or contained open space is provided, egress requirements shall conform to the appropriate requirements for rooms or suites in Article 9.9.7.4.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.